Historical Document
Models 701 and 709 Variable Diode Function Generators
Read the PDF (1 pp) ↗
Single-page product brochure for the Comdyna Models 701 and 709 Variable Diode Function Generators (VDFG). The Model 701 features fixed breakpoints with adjustable slopes and 11 straight-line segments for approximating arbitrary non-linear curves, priced at $165; it includes an internal inverter amplifier so segments can be positive or negative, with functions generated across all four quadrants. The Model 709 extends the capability with both adjustable breakpoints and adjustable slopes, offering 5 positive and 5 negative breakpoints each adjustable anywhere within the full 10 V range, enabling 21 or more segment curve approximations, priced at $205.
- Manufacturer
- Comdyna
- System
- 701, 709
- Type
- Historical Document
- Language
- English
- Learning track
- machine reference
- Pages
- 1
- 701, 709
- Comdyna
- function generators
- diode function generator
- non-linear function approximation
- analog computing peripherals
← Back to the Reference Library
Models 701 and 709 Variable Diode Function Generators
MODELS 701 AND 709
VARIABLE DIODE FUNCTION GENERATORS
MODEL 701
fixed breakpoints, adjustable slopes
°
tno aE aa aaPONTS
>
1e 3
oO
Oe
The 701 is the easy-to-set diode function generator that
can be used with any 10 volt analog computer or re-
lated system. Just patch it to your computer and it’s
ready to generate arbitrary functions. Eleven straight line
segments approximate non-linear curves. Included stand-
ard is an internal inverter amplifier that lets curve seg-
ments have either positive or negative slopes. Arbitrary
functions are generated over a full four quadrants. The
701's easy to set features and low cost makes the unit
excellent for student instruction.
see. $165
. .. JUST PATCH TO YOUR SYSTEM
The VDFG is programmed by connecting it to the summing junction of
a high gain operational amplifier. When this amplifier has a resistor
feedback. the VDFG function ‘appears as its output. Functions are conven:
iently set through use of an oscilloscope disploy or XY plotter. For setting
functions, a negative to positive ramp is made the input. (This romp is
available as the normal Comdyna GP.6 time base sweep, or it may be
programmed on other computers.) If the sweep is the ordinate and the
VDFG amplifier output is the abeissa, the read-out display will show the
input/output curve. In setting the function, first the parallex is adjusted to
establish the curve’s position at the Y axis. Next, the center slope is set.
Other segment slopes are then sct sequentially from the zero position. When
the desired function is displayed, the sweep is replacd by the program
input and the VDFG ts ready for operation.
COMDYNA, Inc.
MODEL 709
adjustable breakpoints, adjustable slopes
Spee 20-660)
Mele) or foMoM oom
vost
Similar in operation to the 701, the 709 VDFG expands
the range of function generation through use of both
variable breakpoints and variable slopes. The eleven
curve segments are provided as five posilive and five
negative breakpoints. Fach may be adjusted to any point
within the full 10 volt range. As with the 701, an in-
ternal inverter amplifier is provided so that individual
segments may be of either positive or negative slope.
Any number of 709 units may be slaved together for
21 or more segment curve approximation.
we $205
FOR ARBITRARY NON-LINEAR FUNCTIONS
SPECIFICATIONS
Number of Segments
Segment Slope (Typical w/SOK feedback) «
Porallex Adjustment.
Power Requirements .
Physical Dimensions .
« plus & minus reference (10 to 154
by FYING
COMPUTERS FOR DYNAMIC ANALYSIS
305 Devonshire Road, Barrington, Illinois 60010, (312) 381-7560